--ESI-MIB { iso org(3) dod(6) internet(1) private(4) enterprises(1) esi(683) }
--Extended Systems MIB.

--Revision 2.2, July 12, 1999

--(C) Copyright 1995, Extended Systems, Inc.


--ESI-MIB { iso org(3) dod(6) internet(1) private(4) enterprises(1) 683 }


ESI-MIB DEFINITIONS ::= BEGIN

IMPORTS
  enterprises, OBJECT-TYPE, NetworkAddress,
  IpAddress, Counter                          FROM RFC1155-SMI
  DisplayString                               FROM RFC1213-MIB
  TRAP-TYPE                                   FROM RFC-1215;

  esi              OBJECT IDENTIFIER ::= { enterprises 683 }
  general          OBJECT IDENTIFIER ::= { esi 1 }
  commands         OBJECT IDENTIFIER ::= { esi 2 }
  esiSNMP          OBJECT IDENTIFIER ::= { esi 3 }
  esiSNMPCommands  OBJECT IDENTIFIER ::= { esiSNMP 2 }
  driver           OBJECT IDENTIFIER ::= { esi 4 }
  tokenRing        OBJECT IDENTIFIER ::= { esi 5 }
  printServers     OBJECT IDENTIFIER ::= { esi 6 }
  psGeneral        OBJECT IDENTIFIER ::= { printServers 1 }
  psOutput         OBJECT IDENTIFIER ::= { printServers 2 }
  psProtocols      OBJECT IDENTIFIER ::= { printServers 3 }
  genProtocols     OBJECT IDENTIFIER ::= { general 15 }
  outputCommands   OBJECT IDENTIFIER ::= { psOutput 2 }
  outputConfigure  OBJECT IDENTIFIER ::= { psOutput 3 }
  outputJobLog     OBJECT IDENTIFIER ::= { psOutput 6 }
  trCommands       OBJECT IDENTIFIER ::= { tokenRing 2 }
  trConfigure      OBJECT IDENTIFIER ::= { tokenRing 3 }
  tcpip            OBJECT IDENTIFIER ::= { psProtocols 1 }
  netware          OBJECT IDENTIFIER ::= { psProtocols 2 }
  vines            OBJECT IDENTIFIER ::= { psProtocols 3 }
  lanManager       OBJECT IDENTIFIER ::= { psProtocols 4 }
  eTalk            OBJECT IDENTIFIER ::= { psProtocols 5 }
  tcpipCommands    OBJECT IDENTIFIER ::= { tcpip 3 }
  tcpipConfigure   OBJECT IDENTIFIER ::= { tcpip 4 }
  tcpipStatus      OBJECT IDENTIFIER ::= { tcpip 5 }
  nwCommands       OBJECT IDENTIFIER ::= { netware 3 }
  nwConfigure      OBJECT IDENTIFIER ::= { netware 4 }
  nwStatus         OBJECT IDENTIFIER ::= { netware 5 }
  bvCommands       OBJECT IDENTIFIER ::= { vines 3 }
  bvConfigure      OBJECT IDENTIFIER ::= { vines 4 }
  bvStatus         OBJECT IDENTIFIER ::= { vines 5 }
  eTalkCommands    OBJECT IDENTIFIER ::= { eTalk 3 }
  eTalkConfigure   OBJECT IDENTIFIER ::= { eTalk 4 }
  eTalkStatus      OBJECT IDENTIFIER ::= { eTalk 5 }

-- object types

-- the general group

genGroupVersion     OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The version for the general group."
    ::= { general 1 }

genMIBVersion OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The version of the MIB."
    ::= { general 2 }

genProductName OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..20))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "A textual description of the device."
    ::= { general 3 }

genProductNumber OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..5))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The product number of the device."
    ::= { general 4 }

genSerialNumber OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..7))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The serial number of the device."
    ::= { general 5 }

genHWAddress OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (6))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The device's hardware address."
    ::= { general 6 }

genCableType OBJECT-TYPE
    SYNTAX  INTEGER {
        tenbase2(1),
        tenbaseT(2),
        aui(3),
        utp(4),
        stp(5),
        fiber100fx(6)
    }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "Indicates the network cable type connected to the
         device."
    ::= { general 7 }

genDateCode OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..10))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The device's datecode."
    ::= { general 8 }

genVersion OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..10))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "A string indicating the version of the firmware."
    ::= { general 9 }

genConfigurationDirty OBJECT-TYPE
    SYNTAX  INTEGER {
        no(1),
        yes(2)
    }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "A variable's value has been changed which will
         require that the device be reset or power cycled
         before it will take effect.
         Set cmdReset to take this action.

         A list of critical variables that will cause
         genConfigurationDirty to be set follows:

         snmpGetCommunityName,
         snmpSetCommunityName,

         trPriority,
         trEarlyTokenRelease,
         trPacketSize,
         trRouting,
         trLocallyAdminAddr,

         psJetAdminEnabled,

         outputType,
         outputHandshake,

         tcpipEnabled,
         tcpipIPAddress,
         tcpipDefaultGateway,
         tcpipSubnetMask,
         tcpipUsingNetProtocols,
         tcpipBootProtocolsEnabled,
         tcpipRawPortNumber,
         tcpipMLPTCPPort,
         tcpipMLPPort,
         
         nwEnabled,
         nwSetFrameFormat,
         nwMode,
         nwPrintServerName,
         nwPrintServerPassword,
         nwQueueScanTime,
         nwFileServerName,
         nwPortPrinterNumber,
         nwPortFontDownload,
         nwPortPCLQueue,
         nwPortPSQueue,
         nwPortFormsOn,
         nwPortNotification,

         bvEnabled,
         bvSetSequencedRouting,
         bvLoginName,
         bvLoginPassword,
         bvPrintServiceName,
         bvPrintServiceRouting,

         lmEnabled,

         eTalkEnabled"
    ::= { general 10 }

genCompanyName OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..30))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "A string indicating the manufacturer of the device."
    ::= { general 11 }

genCompanyLoc OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..30))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "A string indicating the location of the manufacturer
         of the device."
    ::= { general 12 }

genCompanyPhone OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..15))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "A string indicating the phone number of the
         manufacturer of the device."
    ::= { general 13 }

genCompanyTechSupport OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..64))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "A string indicating the technical support information
         for the device."
    ::= { general 14 }

genNumProtocols OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The number of network protocols supported on the
         device."
    ::= { genProtocols 1 }

genProtocolTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF GenProtocolEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
         "A list of network protocols.  The number of
         entries is given by the value of genNumProtocols."
   ::= { genProtocols 2 }

genProtocolEntry OBJECT-TYPE
    SYNTAX  GenProtocolEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
         "A network protocol supported on the device."
    INDEX   { genProtocolIndex }
    ::= { genProtocolTable 1 }

GenProtocolEntry ::=
    SEQUENCE {
        genProtocolIndex
            INTEGER,
        genProtocolDescr
            DisplayString,
        genProtocolID
            INTEGER
    }

genProtocolIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "A unique value for each network protocol.  Its
         value ranges between 1 and the value of
         genNumProtocols.  The value for each protocol must
         remain constant at least from one re-initialization
         of the entity's network management system to the next
         re-initialization."
    ::= { genProtocolEntry 1 }

genProtocolDescr OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..32))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "A textual string describing the network protocol."
    ::= { genProtocolEntry 2 }

genProtocolID OBJECT-TYPE
    SYNTAX  INTEGER {
        tcp-ip(1),
        netware(2),
        vines(3),
        lanmanger(4),
        ethertalk(5)
    }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "A unique identification number for the network
         protocol."
    ::= { genProtocolEntry 3 }

genSysUpTimeString OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..35))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "A string indicating the system up time for the device."
    ::= { general 16 }

-- the commands group

cmdGroupVersion OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The version for the commands group."
::= { commands 1 }

cmdReset OBJECT-TYPE
    SYNTAX  INTEGER {
        no(1),
        yes(2)
    }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
         "A value of 2 will reset the device.  The following
         list of variables will also cause the device to reset
         itself.

         cmdRestoreDefaults,
         snmpRestoreDefaults,
         trRestoreDefaults,
         outputRestoreDefaults,
         tcpipRestoreDefaults,
         tcpipFirmwareUpgrade,
         nwRestoreDefaults,
         nwFirmwareUpgrade,
         bvRestoreDefaults,
         bvFirmwareUpgrade,
         eTalkRestoreDefaults"
::= { commands 2 }

cmdPrintConfig OBJECT-TYPE
    SYNTAX  INTEGER {
        no(1),
        yes(2)
    }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
         "A value of 2 will cause the device to print a
         configuration page."
    ::= { commands 3 }

cmdRestoreDefaults OBJECT-TYPE
    SYNTAX  INTEGER {
        no(1),
        yes(2)
    }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
         "A value of 2 will restore all parameters on the device
         to factory defaults, as well as reset the device."
    ::= { commands 4 }

-- the esiSNMP group

snmpGroupVersion OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The version for the snmp group."
    ::= { esiSNMP 1 }

snmpRestoreDefaults OBJECT-TYPE
    SYNTAX  INTEGER {
        no(1),
        yes(2)
    }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
         "A value of 2 will restore all SNMP parameters
         on the device to factory defaults, as well as reset
         the device."
    ::= { esiSNMPCommands 1 }

snmpGetCommunityName OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (1..31))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
        "Get community name for the managed node.

         In order for changes to this variable to take effect,
         the print server must be reset.  See cmdReset to do
         this."
    ::= { esiSNMP 3 }

snmpSetCommunityName OBJECT-TYPE
     SYNTAX  DisplayString (SIZE (1..31))
     ACCESS  read-write
     STATUS  optional
     DESCRIPTION
          "Set community name for the managed node.  This value
          cannot be read, just set.

          In order for changes to this variable to take effect,
          the print server must be reset.  See cmdReset to do
          this."
::= { esiSNMP 4 }

snmpTrapCommunityName OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (1..31))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
         "Trap community name for the managed node."
    ::= { esiSNMP 5 }

-- the driver group

driverGroupVersion OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The version for the driver group."
    ::= { driver 1 }

driverRXPackets OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The number of packets received."
    ::= { driver 2 }

driverTXPackets OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The number of packets transmitted."
    ::= { driver 3 }

driverRXPacketsUnavailable OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The number of inbound packets which were chosen
         to be discarded even though no errors had been
         detected to prevent their being deliverable to a
         higher-layer protocol due to a lack of buffer space."
    ::= { driver 4 }

driverRXPacketErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The number of inbound packets that contained
         errors preventing them from being deliverable to a
         higher-layer protocol."
    ::= { driver 5 }

driverTXPacketErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The number of outbound packets that could not be
         transmitted because of errors."
    ::= { driver 6 }

driverTXPacketRetries OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The number of retransmitted packets."
    ::= { driver 7 }

driverChecksumErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The number of packets containing checksum errors
         received."
    ::= { driver 8 }

-- the tokenRing group

trGroupVersion OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The version for the tokenRing group."
    ::= { tokenRing 1 }

trRestoreDefaults OBJECT-TYPE
    SYNTAX  INTEGER {
        no(1),
        yes(2)
    }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
         "A value of 2 will restore all token-ring parameters
         on the device to factory defaults, as well as reset
         the device."
    ::= { trCommands 1 }

trPriority OBJECT-TYPE
    SYNTAX  INTEGER (0..6)
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
         "The token which is passed around the ring until a
         station needs it can be assigned a priority from 0 to
         6.  Priority 0 is the lowest and 6 is the highest.  The
         priority of the device can be increased to improve
         performance.  However, the performance of file servers
         and crucial stations could be affected.

         In order for changes to this variable to take effect,
         the device must be reset.  See cmdReset to do this."
         ::= { trConfigure 1 }

trEarlyTokenRelease OBJECT-TYPE
    SYNTAX  INTEGER {
        no(1),
        yes(2)
    }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
         "Early token release allows the device to release the
         token immediately after transmitting data but only on
         16 Mbps systems.  This feature enhances ring performance.

         In order for changes to this variable to take effect,
         the device must be reset.  See cmdReset to do this."
    ::= { trConfigure 2 }

trPacketSize OBJECT-TYPE
    SYNTAX  INTEGER {
        one-k(1),
        two-k(2),
        four-k(3)
    }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
         "You should only change the packet size if you are
         using a driver for your Token Ring adapter which
         allows packet sizes greater than One_K.

         In order for changes to this variable to take effect,
         the device must be reset.  See cmdReset to do this."
    ::= { trConfigure 3 }

trRouting OBJECT-TYPE
    SYNTAX  INTEGER {
        off(1),
        all-None(2),
        single-All(3),
        single-None(4)
    }
   ACCESS  read-write
   STATUS  optional
   DESCRIPTION
        "Set this variable to change the source routing
        configuration on the device.

        Off:  No source routing.

        All, None:  All-routes broadcast, nonbroadcast return.
        The frame will be transmitted on every route within
        the network resulting in multiple copies on a given ring.

        Single, All:  Single-route broadcast, all routes
        broadcast return.  The frame will be transmitted across
        the designated bridges, which will result in the frame
        appearing only once on each ring.  The response frame
        is on all routes broadcast to the originator.

        Single, None:  Single-route broadcast, nonbroadcast
        return.  The frame will be transmitted across designated
        bridges, which will result in the frame appearing only
        once each ring.

         In order for changes to this variable to take effect,
         the device must be reset.  See cmdReset to do this."
    ::= { trConfigure 4 }

trLocallyAdminAddr OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (6))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
         "This is the locally administered node address for the
         device.  Valid values are 000000000000 and between
         400000000000 and 7FFFFFFFFFFF.  A value of 000000000000
         indicates that a locally administered address is not in
         use."
    ::= { trConfigure 5 }

-- the psGeneral group

psGroupVersion OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The version for the psGeneral group."
    ::= { psGeneral 1 }

psJetAdminEnabled OBJECT-TYPE
    SYNTAX  INTEGER {
        no(1),
        yes(2)
    }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
         "Indicates whether or not the JetAdmin support is
         enabled on the print server.

         In order for changes to this variable to take effect,
         the print server must be reset.  See cmdReset to do
         this."
    ::= { psGeneral 2 }

psVerifyConfiguration OBJECT-TYPE
    SYNTAX  INTEGER {
        getvalue(0),
        serial-configuration(1)
    }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
         "This variable is used to force the print server to verify valid configuration
          settings. Setting the variable to the appropriate enumeration will cause the 
          print server to verify the settings for that enumeration. If the settings are
          valid, the result of the set will be OK. If the settings are not valid, the 
          result will be BadValue. Gets on this variable will always return 0. 
         
         1 - Indicates whether or not the current serial configuration is
              valid. 
             Valid configurations - If the serial port is set in bidirectional mode,
             the baud rate must be less than 115200 and the handshaking must be set to 
             hardware handshaking.
             
         2 - Not used yet. 
         "
    ::= { psGeneral 3 }

-- the psOutput group

outputGroupVersion OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The version for the output group."
    ::= { psOutput 1 }

outputRestoreDefaults OBJECT-TYPE
    SYNTAX  INTEGER {
        no(1),
        yes(2)
    }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
         "A value of 2 will restore all output parameters on
         the print server to factory defaults, as well as reset
         the print server."
    ::= { outputCommands 1 }
    
outputCommandsTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF OutputCommandsEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
         "A list of physical output ports.  The number of
         entries is given by the value of outputNumPorts."
    ::= { outputCommands 2 }
    
outputCommandsEntry OBJECT-TYPE
    SYNTAX  OutputCommandsEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "A physical output port on the print server."
    INDEX   { outputIndex }
    ::= { outputCommandsTable 1 }
    
OutputCommandsEntry ::=
    SEQUENCE {
        outputCancelCurrentJob
            INTEGER
    }
    
outputCancelCurrentJob OBJECT-TYPE
    SYNTAX  INTEGER {
        no(1),
        yes(2)
    }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
         "A value of 2 will cancel the job currently printing 
         on that port."
    ::= { outputCommandsEntry 1 }

outputNumPorts OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The number of physical output ports on the print
         server."
    ::= { outputConfigure 1 }

outputTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF OutputEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
         "A list of physical output ports.  The number of
         entries is given by the value of outputNumPorts."
    ::= { outputConfigure 2 }

outputEntry OBJECT-TYPE
    SYNTAX  OutputEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "A physical output port on the print server."
    INDEX   { outputIndex }
    ::= { outputTable 1 }

OutputEntry ::=
    SEQUENCE {
        outputIndex
            INTEGER,
        outputName
            DisplayString,
        outputStatusString
            DisplayString,
        outputStatus
            INTEGER,
        outputExtendedStatus
            INTEGER,
        outputPrinter
            INTEGER,
        outputLanguageSwitching
            INTEGER,
        outputConfigLanguage
            INTEGER,
        outputPCLString
            OCTET STRING,
        outputPSString
            OCTET STRING,
        outputCascaded
            INTEGER,
        outputSetting
            INTEGER,
        outputOwner
            INTEGER,
        outputBIDIStatusEnabled
            INTEGER,
        outputPrinterModel
            DisplayString,
        outputPrinterDisplay
            DisplayString,
        outputCapabilities
            INTEGER,
        outputHandshake
            INTEGER,
        outputDataBits
            INTEGER,
        outputStopBits
            INTEGER,
        outputParity
            INTEGER,
        outputBaudRate
            INTEGER,
        outputProtocolManager
            INTEGER
    }

outputIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "A unique value for each physical output port.
         Its value ranges between 1 and the value of
         outputNumPorts.  The value for each protocol must
         remain constant at least from one re-initialization
         of the entity's network management system to the next
         re-initialization."
    ::= { outputEntry 1 }

outputName OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..15))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
         "A textual description of the output port."
    ::= { outputEntry 2 }

outputStatusString OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..80))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "A string indicating the status of the physical
         output port."
    ::= { outputEntry 3 }

outputStatus OBJECT-TYPE
    SYNTAX  INTEGER  {
        on-Line(1),
        off-Line(2)
    }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "Indicates status of the printer.  Get
         outputExtendedStatus for further information."
    ::= { outputEntry 4 }

outputExtendedStatus OBJECT-TYPE
    SYNTAX  INTEGER  {
        none(1),
        no-Printer-Attached(2),
        toner-Low(3),
        paper-Out(4),
        paper-Jam(5),
        door-Open(6),
        printer-Error(15)
    }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "Indicates printer status to be used in conjunction with
         outputStatus."
    ::= { outputEntry 5 }

outputPrinter OBJECT-TYPE
    SYNTAX  INTEGER {
        hp-III(1),
        hp-IIISi(2),
        ibm(3),
        no-Specific-Printer(4)
    }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
         "The type of printer the output port is attached to.

         Even if the group is supported, this variable may not
         be supported."
::= { outputEntry 6 }

outputLanguageSwitching OBJECT-TYPE
    SYNTAX  INTEGER {
        off(1),
        pcl(2),
        postScript(3),
        als(4)
    }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
         "Indicates the language switching option for the physical
         port.

         Even if the group is supported, this variable may not be
         supported."
    ::= { outputEntry 7 }

outputConfigLanguage OBJECT-TYPE
    SYNTAX  INTEGER {
        text(1),
        pcl(2),
        postScript(3),
        off(4),
        epl-zpl(5)
    }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
         "Indicates the language that configuration pages will be
         printed in.

         If set to off, a config sheet will not be printed on this
         port."
    ::= { outputEntry 8 }

outputPCLString OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (127))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
         "This string will be sent out the physical port if
         (1) outputLanguageSwitching is set to PCL or
         outputLanguageSwitching is set to Auto and the job is
           determined to be PCL, and (2) outputPrinter is set to
           No_Specific_Printer.

           Even if the group is supported, this variable may not be
           supported."
      ::= { outputEntry 9 }

  outputPSString OBJECT-TYPE
      SYNTAX  OCTET STRING (SIZE (127))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "This string will be sent out the physical port if
           (1) outputLanguageSwitching is set to PostScript or
           outputLanguageSwitching is set to Auto and the job is
           determined to be PostScript, and (2) outputPrinter is
           set to No_Specific_Printer.

           Even if the group is supported, this variable may not be
           supported."
      ::= { outputEntry 10 }

  outputCascaded OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A value of 2 indicates that the physical output port is
           connected to an Extended System's printer sharing device.

           Even if the group is supported, this variable may not be
           supported."
      ::= { outputEntry 11 }

  outputSetting OBJECT-TYPE
      SYNTAX  INTEGER {
          serial-infrared(32758),
          serial-bidirectional(32759),
          serial-unidirectional(32760),
          serial-input(32761),
          parallel-compatibility-no-bidi(32762),
          ieee-1284-std-nibble-mode(32763),
          z-Link(32764),
          internal(32765),
          ieee-1284-ecp-or-fast-nibble-mode(32766),
          extendedLink(32767)          
      }
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
           "Indicates the type (and optionally speed) for the
           physical output port.  Setting this variable to physical
           connections (such as Parallel) will result in an error.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { outputEntry 12 }

  outputOwner OBJECT-TYPE
      SYNTAX  INTEGER {
          no-Owner(1),
          tcpip(2),
          netware(3),
          vines(4),
          lanManager(5),
          etherTalk(6),
          config-Page(7)
      }
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
           "Indicates which protocol or task currently is printing on
           the port."
      ::= { outputEntry 13 }

  outputBIDIStatusEnabled OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A value of 2 indicates that the BIDI status system is
            enabled."
      ::= { outputEntry 14 }

  outputPrinterModel OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..60))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "A string indicating the printer model attached to the output port."
      ::= { outputEntry 15 }

  outputPrinterDisplay OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..30))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "A string indicating the message on the attached printer front panel."
      ::= { outputEntry 16 }

  outputCapabilities OBJECT-TYPE
      SYNTAX  INTEGER {
          serial-Uni-Baud-9600(1),
          serial-Uni-Baud-19200(2),
          serial-Uni-Baud-38400(4),
          serial-Uni-Baud-57600(8),
          serial-Uni-Baud-115200(16),
          serial-bidi-Baud-9600(32),
          serial-bidi-Baud-19200(64),
          serial-bidi-Baud-38400(128),
          serial-bidi-Baud-57600(256),
          zpl-epl-capable(262144),
          serial-irin(524288),
          serial-in(1048576),
          serial-config-settings(2097152),
          parallel-compatibility-no-bidi(4194304),
          ieee-1284-std-nibble-mode(8388608),
          z-link(16777216),
          bidirectional(33554432),
          serial-Software-Handshake(67108864),
          serial-Output(134217728),
          extendedLink(268435456),
          internal(536870912),
          ieee-1284-ecp-or-fast-nibble-mode(1073741824)
      }
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
           "This field is implemented as a BIT mask.  If the bit is set then
           the port is capable of functioning in this mode.

           Bit  Property
           ---  ------------------------
           0    Serial Unidirectional Baud 9600
           1    Serial Unidirectional Baud 19200
           2    Serial Unidirectional Baud 38400
           3    Serial Unidirectional Baud 57600
           4    Serial Unidirectional Baud 115200
           5    Serial Bidirectional Baud 9600
           6    Serial Bidirectional Baud 19200
           7    Serial Bidirectional Baud 38400
           8    Serial Bidirectional Baud 57600
           19   Infrared Input on serial port
           20   Serial Input
           21   Serial Configuration Settings
           22   Parallel Compatibility Mode (no bidi)
           23   IEEE 1284 Standard Nibble Mode
           24   ZLink
           25   Bidirectional Support (PJL status)
           26   Serial Software Handshaking
           27   Serial Output
           28   Extended Link Technology
           29   Printer Internal (MIO)
           30   IEEE 1284 ECP or Fast Nibble Mode"
      ::= { outputEntry 17 }

  outputHandshake OBJECT-TYPE
      SYNTAX  INTEGER {
          not-Supported(1),
          hardware-Software(2),
          hardware(3),
          software(4)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "If the port in serial mode operation this indicates the
           handshaking method being used.  Setting this value to 'not-
           supported' will result in an error.  Setting this value on
           non serial capable ports will result in an error.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { outputEntry 18 }

  outputDataBits OBJECT-TYPE
      SYNTAX  INTEGER {
          seven-bits(7),
          eight-bits(8),
          not-Supported(255)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "If the port in serial mode operation this indicates the
           number of data bits being used.  Setting this value to 'not-
           supported' will result in an error.  Setting this value on
           non serial capable ports will result in an error.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { outputEntry 19 }

  outputStopBits OBJECT-TYPE
      SYNTAX  INTEGER {
          one-bit(1),
          two-bits(2),
          not-Supported(255)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "If the port in serial mode operation this indicates the
           number of stop bits being used.  Setting this value to 'not-
           supported' will result in an error.  Setting this value on
           non serial capable ports will result in an error.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { outputEntry 20 }

  outputParity OBJECT-TYPE
      SYNTAX  INTEGER {
          none(1),
          odd(2),
          even(3),
          not-Supported(255)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "If the port in serial mode operation this indicates the
           parity checking method being used.  Setting this value to 'not-
           supported' will result in an error.  Setting this value on
           non serial capable ports will result in an error.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { outputEntry 21 }

  outputBaudRate OBJECT-TYPE
      SYNTAX  INTEGER {
          unidirectional-9600(1),
          unidirectional-19200(2),
          unidirectional-38400(3),
          unidirectional-57600(4),
          unidirectional-115200(5),
          bidirectional-9600(6),
          bidirectional-19200(7),
          bidirectional-38400(8),
          bidirectional-57600(9)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "If the port in serial mode operation this indicates the
           baud rate being used. Setting this value on
           non serial capable ports will result in an error.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { outputEntry 22 }

  outputProtocolManager OBJECT-TYPE
      SYNTAX  INTEGER {
           protocol-none(0),      
           protocol-compatibility(1),
           protocol-1284-4(2)
      }
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           " Indicates the type of output protocol manager being used on the
             port.  Protocol-none means either there is no printer attached or
             the print server has not yet determined which output managers are
             supported on the printer.   Protocol-compatibility means the printer
             does not support any of the protocol managers supported by the print
             server.  Protocol-1284-4 means the output is using the 1284.4 logical
             port protocol manager.
           "
      ::= { outputEntry 23 }

outputDisplayMask OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "Bit mask describing what should be displayed by the utilities
         
          bit   Description
          ---   -----------
          0     outputCancelCurrentJob (Includes all CancelCurrentJob info)  
          1     outputName
          2     outputStatusString
          3     outputStatus
          4     outputExtendedStatus
          5     outputPrinter
          6     outputLanguageSwitching
          7     outputConfigLanguage
          8     outputString (Includes outputPCLString and outputPSString)
          9     outputCascaded
          10    outputSetting
          11    outputOwner
          12    outputBIDIStatusEnabled
          13    outputPrinterModel
          14    outputPrinterDisplay
          15    outputHandshake
          16    outputJobLog  (includes all job logging)
          17    outputSerialConfig"
    ::= { psOutput 4 }

outputAvailableTrapsMask OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "Bit mask describing what output printer traps are available
         
          bit   Description
          ---   -----------
          0     online
          1     offline
          2     printer attached
          3     toner low
          4     paper out
          5     paper jam
          6     door open
          7     printer error"
    ::= { psOutput 5 }

outputNumLogEntries OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The number of job log entries per output port."
    ::= { outputJobLog 1 }

outputJobLogTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF OutputJobLogEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
         "A 2 dimensional list of Job log entries indexed by the output port
         number and the log entry index (1 through outputNumJobLogEntries).  
         The number of entries per output port is given by the value of 
         outputNumJobLogEntries."
    ::= { outputJobLog 2 }

outputJobLogEntry OBJECT-TYPE
    SYNTAX  OutputJobLogEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "A Job log entry."
    INDEX   { outputIndex }
    ::= { outputJobLogTable 1 }

OutputJobLogEntry ::=
    SEQUENCE {
        outputJobLogInformation
            DisplayString,
        outputJobLogTime
            DisplayString
    }

outputJobLogInformation OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..100))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "A textual description of print job information.
         The protocol, source, and file size are always included.  
         Other information such as File Server, Queue, File Name, etc
         will be included if available."
    ::= { outputJobLogEntry 1 }

outputJobLogTime OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..50))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "A string indicating the elasped time since the last job was
         printed. Reported in form X hours X minutes X seconds."
    ::= { outputJobLogEntry 2 }

outputTotalJobTable OBJECT-TYPE
   SYNTAX  SEQUENCE OF OutputTotalJobEntry
   ACCESS  not-accessible
   STATUS  mandatory
   DESCRIPTION
        "Table showing the total number of jobs printed for each port."
   ::= { outputJobLog 3 }

outputTotalJobEntry OBJECT-TYPE
   SYNTAX  OutputTotalJobEntry
   ACCESS  not-accessible
   STATUS  mandatory
   DESCRIPTION
       "An entry in the outputTotalJobTable."
   INDEX   { outputTotalJobIndex }
   ::= { outputTotalJobTable 1 }

OutputTotalJobEntry ::=
   SEQUENCE {
       outputTotalJobIndex
           INTEGER,
       outputTotalJobsLogged
           INTEGER
   }

outputTotalJobIndex OBJECT-TYPE
   SYNTAX  INTEGER
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
        "A unique value for entry in the outputTotalJobTable.
        Its value ranges between 1 and the value of
        numPorts."
   ::= { outputTotalJobEntry 1 }

outputTotalJobsLogged OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The total number of jobs printed by the port since the 
         print server was powered on. "
    ::= { outputTotalJobEntry 2 }
  
  
  -- the tcpip group

  tcpipGroupVersion OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
           "The version for the tcpip group."
      ::= { tcpip 1 }

  tcpipEnabled OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Indicates whether or not the tcpip protocol stack is
           enabled on the print server.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { tcpip 2 }

  tcpipRestoreDefaults OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A value of 2 will restore all tcpip parameters on
           the print server to factory defaults, as well as reset
           the print server."
      ::= { tcpipCommands 1 }

  tcpipFirmwareUpgrade OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A value of 2 will put the print server into firmware
           upgrade mode waiting to receive a firmware upgrade file
           via tftp."
      ::= { tcpipCommands 2 }

  tcpipIPAddress OBJECT-TYPE
      SYNTAX  IpAddress
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The Internet Address.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { tcpipConfigure 1 }

  tcpipDefaultGateway OBJECT-TYPE
      SYNTAX  IpAddress
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The default gateway for the print server.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { tcpipConfigure 2 }

  tcpipSubnetMask OBJECT-TYPE
      SYNTAX  IpAddress
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The subnet mask for the print server.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
  ::= { tcpipConfigure 3 }

  tcpipUsingNetProtocols OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A value of 2 indicates that the print server is using
           a combination of RARP, BOOTP, default IP address, or
           gleaning to determine its IP address.

           See tcpipBootProtocolsEnabled to determine which boot
           protocols are enabled.  If the value of
           tcpipUsingNetProtocols is 1, the IP address is stored
           permanently in flash memory.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { tcpipConfigure 4 }

  tcpipBootProtocolsEnabled OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "This is the 16 bit mask which determines which boot
           protocols will be used to determine the print server's
           IP address.

                      BIT       Boot Protocol Enabled
                      ---       --------------------------
                       0        RARP
                       1        BootP
                       2        DHCP
                       3        Gleaning
                       4        Default Address Enabled (If no address after 2 minutes
                                                  timeout and go to 198.102.102.254) 

           A value of 31 indicates that all boot protocols are
           enabled.  These protocols will only be used if
           tcpipUsingNetProtocols is set to 2.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { tcpipConfigure 5 }

  tcpipIPAddressSource OBJECT-TYPE
      SYNTAX  INTEGER {
          permanent(1),
          default(2),
          rarp(3),
          bootp(4),
          dhcp(5),
          glean(6)
      }
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "This variable indicates how the IP address for the
           print server was determined."
      ::= { tcpipConfigure 6 }

  tcpipIPAddressServerAddress OBJECT-TYPE
      SYNTAX  IpAddress
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "This variable indicates the source of the IP address
           if a boot protocol was used.  This value will be
           0.0.0.0 if no boot server was used."
      ::= { tcpipConfigure 7 }

  tcpipTimeoutChecking OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A value of 2 indicates that a packet timeout
           will be active on all tcp connections.  If a packet has
           not been received from the connection within this timeout the
           connection will be reset.

           To set this timeout, see tcpipTimeoutCheckingValue"
      ::= { tcpipConfigure 8 }

  tcpipNumTraps OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
           "The number of UDP trap destinations."
      ::= { tcpipConfigure 9 }

  tcpipTrapTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF TcpipTrapEntry
      ACCESS  not-accessible
      STATUS  mandatory
      DESCRIPTION
           "A list of UDP trap definitions.  The number of
           entries is given by the value of tcpipNumTraps."
      ::= { tcpipConfigure 10 }

  tcpipTrapEntry OBJECT-TYPE
      SYNTAX  TcpipTrapEntry
      ACCESS  not-accessible
      STATUS  mandatory
      DESCRIPTION
          "An entry in the tcpipTrapTable."
      INDEX   { tcpipTrapIndex }
      ::= { tcpipTrapTable 1 }

  TcpipTrapEntry ::=
      SEQUENCE {
          tcpipTrapIndex
              INTEGER,
          tcpipTrapDestination
              IpAddress,
          tcpipProtocolTrapMask
              INTEGER,
          tcpipPrinterTrapMask
              INTEGER,
          tcpipOutputTrapMask
              INTEGER
      }

  tcpipTrapIndex OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
           "A unique value for entry in the tcpipTrapTable.
           Its value ranges between 1 and the value of
           tcpipNumTraps."
      ::= { tcpipTrapEntry 1 }

  tcpipTrapDestination OBJECT-TYPE
      SYNTAX  IpAddress
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
          "This is the IP address that traps are sent to.
          A value of 0.0.0.0 will disable traps over UDP."
      ::= { tcpipTrapEntry 2 }

  tcpipProtocolTrapMask OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "This is the 16 bit mask which determines which protocol
           specific traps will be sent out via UDP.

           Currently no protocol specific traps are supported."
      ::= { tcpipTrapEntry 3 }

  tcpipPrinterTrapMask OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "This is the 16 bit mask which determines which printer
           specific traps will be sent out via UDP.

           A value of 65535 indicates that all printer specific
           traps should be reported via UDP.

                      BIT       CONDITION
                      ---       --------------------------
                       0        On-line (Condition cleared)
                       1        Off-line
                       2        No printer attached
                       3        Toner Low
                       4        Paper Out
                       5        Paper Jam
                       6        Door Open
                      15        Printer Error"
      ::= { tcpipTrapEntry 4 }

  tcpipOutputTrapMask OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "This is the 16 bit mask which determines which physical
           output ports will be checked when generating printer
           specific traps to be sent out via UDP.

           A value of 65535 indicates that all physical output ports
           will generate traps.

                      BIT       CONDITION
                      ---       --------------------------
                       0        Port 1
                       1        Port 2
                       2        Port 3
                       3        Port 4
                      ...        ..."
      ::= { tcpipTrapEntry 5 }

  tcpipBanners OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A value of 2 indicates that banners will be printed
           with tcpip jobs.

           Even if the group is supported, this variable may not be
           supported."
      ::= { tcpipConfigure 11 }

  tcpipWinsAddress OBJECT-TYPE
      SYNTAX  IpAddress
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The IP address of the WINS server.

            The print server will register its sysName to
            this WINS server."
      ::= { tcpipConfigure 12 }

  tcpipWinsAddressSource OBJECT-TYPE
      SYNTAX  INTEGER {
          dhcp(1),
          permanent(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The source of the WINS server address.

            If set to dhcp, the print server will use the
            WINS address supplied with dhcp.

            If it is set to permanent, it will use the
            WINS address stored in flash."
      ::= { tcpipConfigure 13 }

  tcpipConfigPassword OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (5..24))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The print server html/telnet configuration password.
           This value cannot be read, just set."
      ::= { tcpipConfigure 14 }

  tcpipTimeoutCheckingValue OBJECT-TYPE
      SYNTAX  INTEGER (0..65535)
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The TCP connection timeout in seconds.
            A value of 0 has the same effect as disabling
            timeout checking."
      ::= { tcpipConfigure 15 }

  tcpipArpInterval OBJECT-TYPE
      SYNTAX  INTEGER (0..30)
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The ARP interval in minutes.
            The print server will ARP itself once when
            this timer expires.  Set to 0 to disable."
      ::= { tcpipConfigure 16 }      

  tcpipRawPortNumber OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The raw TCP port number the print server will listen
            for print jobs on.  On multiple port devices, additional
            ports will sequentially follow this port number.
            The default port is 9100.  Setting this value to a TCP
            port that is in use by another TCP application will 
            return an error.
            
            In order for changes to this variable to take effect,
            the print server must be reset.  See cmdReset to do
            this."
      ::= { tcpipConfigure 17 }
      
  tcpipNumSecurity OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
           "The number of secure IP address ranges."
      ::= { tcpipConfigure 18 }  
  
  tcpipSecurityTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF TcpipSecurityEntry
      ACCESS  not-accessible
      STATUS  mandatory
      DESCRIPTION
           "A list of secure IP address ranges.  This adds security for both
           printing and admin rights. 
           
           AdminEnabled: When the admin enabled field is set to yes for a secure
           address range, the print server may only be configured via IP from 
           IP address within that range. If the admin field is not set for any address
           ranges, the print server will accept admin commands from any IP address 
           which has the valid community names and/or passwords. 
           
           PortMask: When there is a port mask set for a secure IP address range, the 
           print server will only accept TCP/IP print jobs from hosts that are in the
           secure address range.  If there are no ranges with a port mask set, the print
           server will accept TCP/IP print jobs from any host.
           
           The number of entries is given by the value of tcpipNumSecurity."
      ::= { tcpipConfigure 19 }

  tcpipSecurityEntry OBJECT-TYPE
      SYNTAX  TcpipSecurityEntry
      ACCESS  not-accessible
      STATUS  mandatory
      DESCRIPTION
          "An entry in the tcpipSecurityTable."
      INDEX   { tcpipSecurityIndex }
      ::= { tcpipSecurityTable 1 }

  TcpipSecurityEntry ::=
      SEQUENCE {
          tcpipSecurityIndex
              INTEGER,
          tcpipSecureStartIPAddress
              IpAddress,
          tcpipSecureEndIPAddress
              IpAddress,
          tcpipSecurePrinterMask
              INTEGER,
          tcpipSecureAdminEnabled
              INTEGER
      }

  tcpipSecurityIndex OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
           "A unique value for entry in the tcpipSecurityTable.
           Its value ranges between 1 and the value of
           tcpipNumSecurity."
      ::= { tcpipSecurityEntry 1 }

  tcpipSecureStartIPAddress OBJECT-TYPE
      SYNTAX  IpAddress
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
          "This is the starting IP address for the secure IP
          address range.  A value of 0.0.0.0 for both
          tcpipStartIPAddress and tcpipEndIPAddress will 
          disable the address range."
      ::= { tcpipSecurityEntry 2 }

  tcpipSecureEndIPAddress OBJECT-TYPE
      SYNTAX  IpAddress
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
          "This is the ending IP address for the secure IP
          address range.  A value of 0.0.0.0 for both
          tcpipStartIPAddress and tcpipEndIPAddress will 
          disable the address range."
      ::= { tcpipSecurityEntry 3 }

  tcpipSecurePrinterMask OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "This is the 8 bit mask which determines which physical
           output ports this range of IP addresses can print to.
           A value of 127 indicates that the range of IP addresses
           can print to any of the output ports.
           
           This value can not be configured until a valid start and 
           end address range have been configured.


                      BIT       CONDITION
                      ---       --------------------------
                       0        Port 1
                       1        Port 2
                       2        Port 3
                       3        Port 4
                      ...        ...
                       8        Reserved, must be set to 0."
      ::= { tcpipSecurityEntry 4 }
      
  tcpipSecureAdminEnabled OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           " This allows an advanced level of admin security for IP. Setting this will 
           restrict which IP addresses can configure the print server. The 
           correct community names and passwords are still required if this is used, it
           just adds another level of security. 
            
           Indicates whether or not admin rights are enabled for this range of 
           IP addresses. If no range of addresses has this enabled, then any IP address
           can configure the print server if it has the correct community names and/or
           passwords. If this field is set to yes for any range of addresses, the 
           print server will only be configurable via IP from that range of addresses.
           
           This value can not be configured until a valid start and end address range 
           have been configured."
           
      ::= { tcpipSecurityEntry 5 }
  
  tcpipLowBandwidth OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A value of 2 will optimize the TCP stack for low bandwidth
            networks.  A value of 1 will optimize the TCP stack for high
            bandwidth networks."
      ::= { tcpipConfigure 20 }
      
  tcpipNumLogicalPrinters OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
           "The number of available logical printers."
      ::= { tcpipConfigure 21 }  
  
  tcpipMLPTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF TcpipMLPEntry
      ACCESS  not-accessible
      STATUS  mandatory
      DESCRIPTION
           "A table of the available logical printers.
           The number of entries is given by the value of tcpipNumLogicalPrinters."
      ::= { tcpipConfigure 22 }

  tcpipMLPEntry OBJECT-TYPE
      SYNTAX  TcpipMLPEntry
      ACCESS  not-accessible
      STATUS  mandatory
      DESCRIPTION
          "An entry in the tcpipMLPTable."
      INDEX   { tcpipMLPIndex }
      ::= { tcpipMLPTable 1 }

  TcpipMLPEntry ::=
      SEQUENCE {
          tcpipMLPIndex
              INTEGER,
          tcpipMLPName
              DisplayString,
          tcpipMLPPort
              INTEGER,
          tcpipMLPTCPPort
              INTEGER,
          tcpipMLPPreString
              DisplayString,
          tcpipMLPPostString
              DisplayString,
          tcpipMLPDeleteBytes
              INTEGER
      }

  tcpipMLPIndex OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "A unique value for entry in the tcpipMLPTable.
            Its value ranges between 1 and the value of
            tcpipNumLogicalPrinters."
      ::= { tcpipMLPEntry 1 }


  tcpipMLPName OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..20))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Contains the name of the logical printer.  This name is also
            the LPR remote queue name associated with the logical printer."
      ::= { tcpipMLPEntry 2 }
      
  tcpipMLPPort OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The number of the physical output port associated with the logical
            printer.
            
            In order for changes to this variable to take effect,
            the print server must be reset.  See cmdReset to do
            this."
      ::= { tcpipMLPEntry 3 }
      
  tcpipMLPTCPPort OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The TCP port associated with the logical printer.  Any print data
            sent to this TCP port will be processed through this logical
            printer entry.
            
            In order for changes to this variable to take effect,
            the print server must be reset.  See cmdReset to do
            this."
      ::= { tcpipMLPEntry 4 }
      
  tcpipMLPPreString OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..64))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "This contains any data that should be sent down to the printer
            at the beginning of jobs sent to this logical printer.  To enter
            non-printable ascii characters in the string, enclose the decimal 
            value inside of <>.  For example, to enter an ESC-E the string would 
            be '<27>E'."
      ::= { tcpipMLPEntry 5 }
      
  tcpipMLPPostString OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..64))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "This contains any data that should be sent down to the printer
            at the end of jobs sent to this logical printer.  To enter
            non-printable ascii characters in the string, enclose the decimal 
            value inside of <>.  For example, to enter an ESC-E the string would 
            be '<27>E'."
      ::= { tcpipMLPEntry 6 }

  tcpipMLPDeleteBytes OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The number of bytes that will be deleted from the beginning of
            jobs sent to this logical printer."
      ::= { tcpipMLPEntry 7 }

  tcpipSmtpServerAddr OBJECT-TYPE
      SYNTAX  IpAddress
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The IP address of the e-mail server which will be used to send e-mail
           notification of printer status conditions. This address must contain the 
           valid IP address of an e-mail server before any of the contents of the 
           SmtpTable are used."
      ::= { tcpipConfigure 23 }

  tcpipNumSmtpDestinations OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
           "The number of configurable e-mail destinations to receive
            printer status conditions. "
      ::= { tcpipConfigure 24 }

  tcpipSmtpTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF TcpipSmtpEntry
      ACCESS  not-accessible
      STATUS  mandatory
      DESCRIPTION
           "A list of SMTP e-mail addresses and printer status conditions
           to send e-mails for. The number of entries is given by the 
           value of tcpipNumSmtpDestinations."
      ::= { tcpipConfigure 25 }

  tcpipSmtpEntry OBJECT-TYPE
      SYNTAX  TcpipSmtpEntry
      ACCESS  not-accessible
      STATUS  mandatory
      DESCRIPTION
          "An entry in the tcpipSmtpTable."
      INDEX   { tcpipSmtpIndex }
      ::= { tcpipSmtpTable 1 }

  TcpipSmtpEntry ::=
      SEQUENCE {
          tcpipSmtpIndex
              INTEGER,
          tcpipSmtpEmailAddr
              OCTET STRING,
          tcpipSmtpProtocolMask
              INTEGER,
          tcpipSmtpPrinterMask
              INTEGER,
          tcpipSmtpOutputMask
              INTEGER
      }

  tcpipSmtpIndex OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
           "A unique value for entry in the tcpipSmtpTable.
           Its value ranges between 1 and the value of
           tcpipNumSmtpDestinations."
      ::= { tcpipSmtpEntry 1 }

  tcpipSmtpEmailAddr OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (64))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
          "This is the e-mail address that printer status conditions 
          are sent to. If this string is empty the status conditions will
          not be sent."
      ::= { tcpipSmtpEntry 2 }

  tcpipSmtpProtocolMask OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "This is the 16 bit mask which determines which protocol
           specific conditions will be sent out via e-mail.

           Currently no protocol specific conditions are supported."
      ::= { tcpipSmtpEntry 3 }

  tcpipSmtpPrinterMask OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "This is the 16 bit mask which determines which printer
           specific conditions will be sent out via e-mail.

           A value of 65535 indicates that all printer specific
           conditions should be reported via e-mail.

                      BIT       CONDITION
                      ---       --------------------------
                       0        On-line (Condition cleared)
                       1        Off-line
                       2        No printer attached
                       3        Toner Low
                       4        Paper Out
                       5        Paper Jam
                       6        Door Open
                      15        Printer Error"
      ::= { tcpipSmtpEntry 4 }

  tcpipSmtpOutputMask OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "This is the 16 bit mask which determines which physical
           output ports will be checked when generating printer
           specific conditions to be sent out via e-mail.

           A value of 65535 indicates that all physical output ports
           will generate e-mails upon a change in status.

                      BIT       CONDITION
                      ---       --------------------------
                       0        Port 1
                       1        Port 2
                       2        Port 3
                       3        Port 4
                      ...        ..."
      ::= { tcpipSmtpEntry 5 }

  tcpipWebAdminName OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (25))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
          "This is the admin name used by web configuration for login."
      ::= { tcpipConfigure 26 }

  tcpipWebAdminPassword OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (25))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
          "This is the admin password used by web configuration for login."
      ::= { tcpipConfigure 27 }

  tcpipWebUserName OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (25))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
          "This is the user name used by web configuration for login. Not
           currently used. "
      ::= { tcpipConfigure 28 }

  tcpipWebUserPassword OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (25))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
          "This is the user password used by web configuration for login. Not
          currently used."
      ::= { tcpipConfigure 29 }

  tcpipWebHtttpPort OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The port number used to communicate over http. Must be between 0 and 
           65535. It must not be the same as any other port used. Other ports used are
           20, 21, 23, 515, & raw port numbers (9100, 9101, ...  if at default)" 
      ::= { tcpipConfigure 30 }

  tcpipWebFaqURL OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (64))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
          "This is the URL for FAQ at the ESI (or other OEM) website."
      ::= { tcpipConfigure 31 }

  tcpipWebUpdateURL OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (64))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
          "This is the URL for finding firmware updates at the ESI 
          (or other OEM) website."
      ::= { tcpipConfigure 32 }

  tcpipWebCustomLinkName OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (25))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
          "This is the name assigned to the custom link defined by the user."
      ::= { tcpipConfigure 33 }

  tcpipWebCustomLinkURL OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (64))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
          "This is the URL for a custom link specified by the user."
      ::= { tcpipConfigure 34 }

  tcpipPOP3ServerAddress OBJECT-TYPE
      SYNTAX  IpAddress
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The IP address of the POP3 server from which email will be retrieved. 
           This address must contain the valid IP address of a POP3 server before 
           any attempts to retrieve email will be made."
      ::= { tcpipConfigure 35 }

  tcpipPOP3PollInterval OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
           "The number of seconds between attempts to retrieve mail from the 
           POP3 server. "
      ::= { tcpipConfigure 36 }

  tcpipPOP3UserName OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (64))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
          "This is the user name for the print server's email account on 
          the POP3 server."
      ::= { tcpipConfigure 37 }

  tcpipPOP3Password OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (20))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
          "This is the password for the print server's email account on
          the POP3 server."
      ::= { tcpipConfigure 38 }

  tcpipDomainName OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (64))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
          "This is the Domain name used by POP3 and SMTP."
      ::= { tcpipConfigure 39 }
            
  tcpipError OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..80))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "Contains any tcpip specific error information."
      ::= { tcpipStatus 1 }

  tcpipDisplayMask OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
         "Bit mask describing what should be displayed by the utilities
         
          bit   Description
          ---   -----------
          0     tcpipAddress (Includes tcpipDefaultGateway and tcpipSubnetMask)
          1     tcpipUsingNetProtocols (Includes tcpipBootProtocolsEnabled, tcpipAddressSource,                                                                tcpipAddressServerAddress)
          2     tcpipTimeoutChecking
          3     tcpipTraps (Includes all trap info)
          4     tcpipBanners
          5     tcpipSecurity (Includes all security info)
          6     tcpipWinsAddress (Includes tcpipWinsAddressSource)
          7     tcpipConfigPassword
          8     tcpipTimeoutCheckingValue
          9     tcpipArpInterval
          10    tcpipRawPortNumber
          11    tcpipError
          12    tcpipLowBandwidth
          13    tcpipMLP (Includes all logical printer settings)"
      ::= { tcpip 6 }
  
  -- the netware group

  nwGroupVersion OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
           "The version for the netware group."
      ::= { netware 1 }

  nwEnabled OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Indicates whether or not the NetWare protocol stack is
           enabled on the print server.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { netware 2 }

  nwRestoreDefaults OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A value of 2 will restore all NetWare parameters on
           the print server to factory defaults, as well as reset
           the print server."
  ::= { nwCommands 1 }

  nwFirmwareUpgrade OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A value of 2 will put the print server into firmware
           upgrade mode."
      ::= { nwCommands 2 }

  nwFrameFormat OBJECT-TYPE
      SYNTAX  INTEGER {
          unknown(1),
          ethernet-II(2),
          ethernet-802-3(3),
          ethernet-802-2(4),
          ethernet-Snap(5),
          token-Ring(6),
          token-Ring-Snap(7)
      }
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "Indicates the frame format that the print server is
           using.  See nwSetFrameFormat to determine which frame
           frame format the print server is configured for."
      ::= { nwConfigure 1 }

  nwSetFrameFormat OBJECT-TYPE
      SYNTAX  INTEGER {
          auto-Sense(1),
          forced-Ethernet-II(2),
          forced-Ethernet-802-3(3),
          forced-Ethernet-802-2(4),
          forced-Ethernet-Snap(5),
          forced-Token-Ring(6),
          forced-Token-Ring-Snap(7)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Indicates the frame format that the print server is
           using.  Setting this value to 1 (Auto_Sense) indicates
           that automatic frame format sensing will be used.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { nwConfigure 2 }

  nwMode OBJECT-TYPE
      SYNTAX  INTEGER {
          unknown(1),
          pserver(2),
          rprinter(3)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Mode the print server is running in.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { nwConfigure 3 }

  nwPrintServerName OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..47))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Contains print server name.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { nwConfigure 4 }

  nwPrintServerPassword OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..9))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The print server password.  This value cannot be read,
           just set.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { nwConfigure 5 }

  nwQueueScanTime OBJECT-TYPE
      SYNTAX  INTEGER (1..255)
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Determines how often, in tenths of a second that the
           print server will scan the queues for jobs.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { nwConfigure 6 }

  nwNetworkNumber OBJECT-TYPE
      SYNTAX  OCTET STRING (SIZE (4))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "The print server's network number."
      ::= { nwConfigure 7 }

  nwMaxFileServers OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "The print server maximum number of file servers which
           it can be attached to at once."
      ::= { nwConfigure 8 }

  nwFileServerTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF NwFileServerEntry
      ACCESS  not-accessible
      STATUS  optional
      DESCRIPTION
           "A table of file servers to service."
      ::= { nwConfigure 9 }

  nwFileServerEntry OBJECT-TYPE
      SYNTAX  NwFileServerEntry
      ACCESS  not-accessible
      STATUS  optional
      DESCRIPTION
           "A file server for the print server to service."
      INDEX   { nwFileServerIndex }
      ::= { nwFileServerTable 1 }

  NwFileServerEntry ::=
      SEQUENCE {
          nwFileServerIndex
              INTEGER,
          nwFileServerName
              DisplayString,
          nwFileServerConnectionStatus
              INTEGER
      }

  nwFileServerIndex OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "A unique value for each file server.  Its value
           ranges between 1 and the value of nwMaxFileServers.
           The value for each server must remain constant at
           least from one re-initialization of the entity's
           network management system to the next
           re-initialization.  The first entry in the table is
           the default file server."
      ::= { nwFileServerEntry 1 }

  nwFileServerName OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..47))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The file server name.  This name will be NULL if there
           is no file server to be serviced.  Only the default
           file server (the first entry in the table) can be set.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { nwFileServerEntry 2 }

  nwFileServerConnectionStatus OBJECT-TYPE
      SYNTAX  INTEGER {
          up(1),
          down(2),
          startupInProgress(3),
          serverReattaching(4),
          serverNeverAttached(5),
          pse-UNKNOWN-FILE-SERVER(258),
          pse-NO-RESPONSE(261),
          pse-CANT-LOGIN(276),
          pse-NO-SUCH-QUEUE(512),
          pse-UNABLE-TO-ATTACH-TO-QUEUE(515),
          bad-CONNECTION(768),
          bad-SERVICE-CONNECTION(769),
          other(32767)
      }
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "The value describes the status of the connection
           between the file server and the print server."
      ::= { nwFileServerEntry 3 }

  nwPortTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF NwPortEntry
      ACCESS  not-accessible
      STATUS  optional
      DESCRIPTION
           "A table of NetWare port specific information."
      ::= { nwConfigure 10 }

  nwPortEntry OBJECT-TYPE
      SYNTAX  NwPortEntry
      ACCESS  not-accessible
      STATUS  optional
      DESCRIPTION
           "An entry of NetWare port specific information."
      INDEX   { nwPortIndex }
      ::= { nwPortTable 1 }

  NwPortEntry ::=
      SEQUENCE {
          nwPortIndex
              INTEGER,
          nwPortStatus
              DisplayString,
          nwPortPrinterNumber
              INTEGER,
          nwPortFontDownload
              INTEGER,
          nwPortPCLQueue
              DisplayString,
          nwPortPSQueue
              DisplayString,
          nwPortFormsOn
              INTEGER,
          nwPortFormNumber
              INTEGER,
          nwPortNotification
              INTEGER
      }

  nwPortIndex OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "A unique value for each physical output port.  Its
           value ranges between 1 and the value of outputNumPorts.
           The value for each port must remain constant at least
           from one re-initialization of the entity's network
           management system to the next re-initialization."
      ::= { nwPortEntry 1 }

  nwPortStatus OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..80))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "A string indicating the NetWare specific status of the
           physical output port."
      ::= { nwPortEntry 2 }

  nwPortPrinterNumber OBJECT-TYPE
      SYNTAX  INTEGER (0..255)
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Indicates the printer number for the print server to
           use when running in RPRinter mode.  A value of 255
           indicates that the port is unconfigured for RPRinter
           mode.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
  ::= { nwPortEntry 3 }

  nwPortFontDownload OBJECT-TYPE
      SYNTAX  INTEGER {
          disabled(1),
          enabled-No-Power-Sense(2),
          enabled-Power-Sense(3)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "This variable controls the font downloading feature
           of the print server.

           Disabled - Do not download fonts.

           Enabled, without Printer Sense - Only download fonts
           after the print server has been reset or power cycled.

           Enabled, with Printer Sense - Download fonts after the
           print server has been reset or power-cycled, or after
           the printer has been power-cycled.  This option is only
           available on certain print servers.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { nwPortEntry 4 }

  nwPortPCLQueue OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..47))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A string indicating the name of the queue containing
           the PCL fonts to download when font downloading is
           enabled.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { nwPortEntry 5 }

  nwPortPSQueue OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..47))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A string indicating the name of the queue containing
           the PS fonts to download when font downloading is
           enabled.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { nwPortEntry 6 }

  nwPortFormsOn OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A value of 2 will enable forms checking.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { nwPortEntry 7 }

  nwPortFormNumber OBJECT-TYPE
      SYNTAX  INTEGER (0..255)
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Indicates the form number to check jobs against
           when nwPortFormsOn is enabled."
      ::= { nwPortEntry 8 }

  nwPortNotification OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A value of 2 will enable job notification."
      ::= { nwPortEntry 9 }

  nwNumTraps OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
           "The number of IPX trap destinations."
      ::= { nwConfigure 11 }

  nwTrapTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF NwTrapEntry
      ACCESS  not-accessible
      STATUS  mandatory
      DESCRIPTION
           "A list of IPX trap definitions.  The number of
           entries is given by the value of nwNumTraps."
      ::= { nwConfigure 12 }

  nwTrapEntry OBJECT-TYPE
      SYNTAX  NwTrapEntry
      ACCESS  not-accessible
      STATUS  mandatory
      DESCRIPTION
          "An entry in the nwTrapTable."
      INDEX   { nwTrapIndex }
      ::= { nwTrapTable 1 }

  NwTrapEntry ::=
      SEQUENCE {
          nwTrapIndex
              INTEGER,
          nwTrapDestination
              OCTET STRING,
          nwTrapDestinationNet
              OCTET STRING,
          nwProtocolTrapMask
              INTEGER,
          nwPrinterTrapMask
              INTEGER,
          nwOutputTrapMask
              INTEGER
      }

  nwTrapIndex OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
           "A unique value for entry in the nwTrapTable.
           Its value ranges between 1 and the value of
           nwNumTraps."
      ::= { nwTrapEntry 1 }

  nwTrapDestination OBJECT-TYPE
      SYNTAX  OCTET STRING (SIZE (6))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
          "This is the network address that IPX traps are sent to.
          A value of 00 00 00 00 00 00 in conjunction with a
          nwTrapDestinationNet of 00 00 00 00 will disable traps
          over IPX."
      ::= { nwTrapEntry 2 }

  nwTrapDestinationNet OBJECT-TYPE
      SYNTAX  OCTET STRING (SIZE (4))
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
           "This is the network number that IPX traps are sent to.
           A value of 00 00 00 00 in conjunction with a
           nwTrapDestination of 00 00 00 00 00 00 will disable
           traps over IPX."
      ::= { nwTrapEntry 3 }

  nwProtocolTrapMask OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "This is the 16 bit mask which determines which protocol
           specific traps will be sent out via IPX.

           Currently no protocol specific traps are supported."
      ::= { nwTrapEntry 4 }

  nwPrinterTrapMask OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "This is the 16 bit mask which determines which printer
           specific traps will be sent out via IPX.

           A value of 65535 indicates that all printer specific
           traps should be reported via IPX.

                      BIT       CONDITION
                      ---       --------------------------
                       0        On-line (Condition cleared)
                       1        Off-line
                       2        No printer attached
                       3        Toner Low
                       4        Paper Out
                       5        Paper Jam
                       6        Door Open
                      15        Printer Error"
      ::= { nwTrapEntry 5 }

  nwOutputTrapMask OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "This is the 16 bit mask which determines which physical
           output ports will be checked when generating printer
           specific traps to be sent out via IPX.

           A value of 65535 indicates that all physical output ports
           will generate traps.

                      BIT       CONDITION
                      ---       --------------------------
                       0        Port 1
                       1        Port 2
                       2        Port 3
                       3        Port 4
                      ...        ..."
      ::= { nwTrapEntry 6 }


  nwNDSPrintServerName OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..512))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
        "Directory Services object used by the print server to
         connect to the NDS tree.  This string contains the entire
         canonicalized name.

         NOTE: This variable must be stored in Unicode."
      ::= { nwConfigure 13 }

  nwNDSPreferredDSTree OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..47))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
        "Directory Services tree to which the NDS print server
         initially connects."
      ::= { nwConfigure 14 }

  nwNDSPreferredDSFileServer OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..47))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
        "The NetWare server to which the NDS print server initially
         makes a bindery connection."
      ::= { nwConfigure 15 }

  nwNDSPacketCheckSumEnabled OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
        "Compute the checksum for packets.

                1 = disabled
                2 = enabled"
      ::= { nwConfigure 16 }

  nwNDSPacketSignatureLevel OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
        "Packet signature is a security method to prevent
         packet forging.

                1 = disabled
                2 = enabled
                3 = preferred
                4 = required"
      ::= { nwConfigure 17 }

  nwAvailablePrintModes OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
        "Reports which NetWare print modes are available.

                      BIT       CONDITION
                      ---       --------------------------
                       0        PServer
                       1        RPrinter
                       2        NDS
                       3        SPX Direct
                       4        JetAdmin
        "
      ::= { nwConfigure 18 }

  nwDirectPrintEnabled OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
        "Indicates whether or not direct mode ipx/spx
         printing is enabled."
      ::= { nwConfigure 19 }

  nwJAConfig OBJECT-TYPE
      SYNTAX INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
        "Indicates whether or not JetAdmin was used to configure
         the netware settings."
      ::= { nwConfigure 20 }

  nwDisableSAP OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
        "Indicates whether or not SAPs are enabled."
      ::= { nwConfigure 21 }

  nwError OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..160))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "Contains any NetWare specific error information."
      ::= { nwStatus 1 }

  nwDisplayMask OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
         "Bit mask describing what should be displayed by the utilities
         
          bit   Description
          ---   -----------
          0     nwFrameFormat
          1     nwJetAdmin
          2     nwFileServer (Includes all file server info)
          3     nwMode
          4     nwPrintServerName
          5     nwPrintServerPassword
          6     nwQueueScanTime
          7     nwNetworkNumber
          8     nwPortStatus
          9     nwPortPrinterNumber
          10    nwPortFontDownload (Includes nwPortPCLQueue and nwPortPSQueue)
          11    nwPortFormsOn (Includes nwPortFormsNumber)
          12    nwPortNotification
          13    nwTraps (Includes all trap info)
          14    nwNDSPrintServerName
          15    nwNDSPreferredDSTree
          16    nwNDSPreferredDSFileServer
          17    nwNDSPacketCheckSumEnabled
          18    nwNDSPacketSignatureLevel
          19    nwDirectPrintEnabled
          20    nwError
          21    nwSapDisable"
      ::= { netware 6 }
  
  -- the vines group

  bvGroupVersion OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
           "The version for the vines group."
      ::= { vines 1 }

  bvEnabled OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Indicates whether or not the Banyan VINES protocol
           stack is enabled on the print server."
      ::= { vines 2 }

  bvRestoreDefaults OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A value of 2 will restore all VINES parameters on
           the print server to factory defaults, as well as reset
           the device."
      ::= { bvCommands 1 }

  bvFirmwareUpgrade OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A value of 2 will put the print server into firmware
           upgrade mode."
     ::= { bvCommands 2 }

  bvSetSequenceRouting OBJECT-TYPE
      SYNTAX  INTEGER {
          automatic-Routing(1),
          force-Sequenced-Routing(2),
          force-Non-Sequenced-Routing(3)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Sets the VINES Routing selection.

           Automatic - Utilizes Sequenced Routing if available,
                       otherwise uses Non-Sequenced Routing.

           Force-Sequenced - Will only use Sequenced Routing.

           Force-Non-Sequenced - Will only use Non-Sequenced Routing

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this.

           WARNING - Sequential Routing requires a VINES 5.5 or
           greater server on the same subnet."
      ::= { bvCommands 3 }

  bvDisableVPMan OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A value of 2 will disable VPMan access to the print
           server for one minute."
      ::= { bvCommands 4 }

  bvLoginName OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (5..63))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The StreetTalk name the device will use to login with.
           This value will be ESIxxxxxxxx where xxxxxxx is the Serial
           number of the device if it is unconfigured.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { bvConfigure 1 }

  bvLoginPassword OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..15))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The password for the login name, bvLoginName.  This value
           cannot be read, just set.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { bvConfigure 2 }

  bvNumberPrintServices OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "The number of Print Services this device supports."
      ::= { bvConfigure 3 }

  bvPrintServiceTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF BvPrintServiceEntry
      ACCESS  not-accessible
      STATUS  optional
      DESCRIPTION
           "Table of Print Services for this device."
      ::= { bvConfigure 4 }

  bvPrintServiceEntry OBJECT-TYPE
      SYNTAX  BvPrintServiceEntry
      ACCESS  not-accessible
      STATUS  optional
      DESCRIPTION
           "Print Services Table entry."
      INDEX   { bvPrintServiceIndex }
      ::= { bvPrintServiceTable 1 }

  BvPrintServiceEntry ::=
      SEQUENCE {
          bvPrintServiceIndex
              INTEGER,
          bvPrintServiceName
              DisplayString,
          bvPrintServiceRouting
              INTEGER
      }

  bvPrintServiceIndex OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "A unique value for each print service."
      ::= { bvPrintServiceEntry 1 }

  bvPrintServiceName OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..63))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The StreetTalk Name for this Print Service.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { bvPrintServiceEntry 2 }

  bvPrintServiceRouting OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "The output port that the print service will print to.
           This value will range from 0 to the number of output ports,
           see outputNumPorts.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { bvPrintServiceEntry 3 }
      
  bvPnicDescription OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..255))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Contains the VINES PNIC description."
      ::= { bvConfigure 5 }

  bvError OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..48))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "Contains any VINES specific error information."
      ::= { bvStatus 1 }

  bvRouting OBJECT-TYPE
      SYNTAX  INTEGER {
          sequenced-Routing(1),
          non-Sequenced-Routing(2),
          unknown-Routing(32766),
          protocol-Disabled(32767)
      }
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "The current VINES Routing being used by the device."
      ::= { bvStatus 2 }

  bvNumPrintServices OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "The number of Print Services this device supports."
      ::= { bvStatus 3 }

  bvPrintServiceStatusTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF BvPrintServiceStatusEntry
      ACCESS  not-accessible
      STATUS  optional
      DESCRIPTION
           "Table of Print Service Status Entry's."
      ::= { bvStatus 4 }

  bvPrintServiceStatusEntry OBJECT-TYPE
      SYNTAX  BvPrintServiceStatusEntry
      ACCESS  not-accessible
      STATUS  optional
      DESCRIPTION
           "Print Service Status Entry."
      INDEX   { bvPSStatusIndex }
      ::= { bvPrintServiceStatusTable 1 }

  BvPrintServiceStatusEntry ::=
      SEQUENCE {
          bvPSStatusIndex
              INTEGER,
          bvPSName
              DisplayString,
          bvPSStatus
              DisplayString,
          bvPSDestination
              INTEGER,
          bvPrinterStatus
              DisplayString,
          bvJobActive
              INTEGER,
          bvJobSource
              DisplayString,
          bvJobTitle
              DisplayString,
          bvJobSize
              DisplayString,
          bvJobNumber
              DisplayString
      }

  bvPSStatusIndex OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "A unique value for each status entry."
      ::= { bvPrintServiceStatusEntry 1 }

  bvPSName OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..63))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "The StreetTalk Name for this Print Service."
      ::= { bvPrintServiceStatusEntry 2 }

  bvPSStatus  OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..48))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "Print Service Status."
      ::= { bvPrintServiceStatusEntry 3 }

  bvPSDestination OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "Port Destination for this print service."
      ::= { bvPrintServiceStatusEntry 4 }

  bvPrinterStatus OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..80))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
          "Printer status for this Print Service."
      ::= { bvPrintServiceStatusEntry 5 }

  bvJobActive OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "Whether there is a VINES job active for this print
           service."
      ::= { bvPrintServiceStatusEntry 6 }

  bvJobSource  OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..64))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "The active print jobs source."
      ::= { bvPrintServiceStatusEntry 7 }

  bvJobTitle  OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..64))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "The title of the active print job."
      ::= { bvPrintServiceStatusEntry 8 }

  bvJobSize  OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..9))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "The size of the active print job."
      ::= { bvPrintServiceStatusEntry 9 }

  bvJobNumber  OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..4))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
          "The VINES job number of the active print job."
      ::= { bvPrintServiceStatusEntry 10 }

  -- the LanMan group

  lmGroupVersion OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
           "The version for the lanManger group."
      ::= { lanManager 1 }

  lmEnabled OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
          "Indicates whether or not the Lan Manager protocol
          stack is enabled on the print server.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { lanManager 2 }

  -- the eTalk group

  eTalkGroupVersion OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
           "The version for the eTalk group."
      ::= { eTalk 1 }

  eTalkEnabled OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Indicates whether or not the EtherTalk protocol
           stack is enabled on the print server.

           In order for changes to this variable to take effect,
           the print server must be reset.  See cmdReset to do
           this."
      ::= { eTalk 2 }

  eTalkRestoreDefaults OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "A value of 2 will restore all EtherTalk parameters on
           the print server to factory defaults, as well as reset
           the print server."
      ::= { eTalkCommands 1 }

  eTalkNetwork OBJECT-TYPE
      SYNTAX  OCTET STRING (SIZE (2))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "Indicates the EtherTalk network number that the print
           server is currently using."
      ::= { eTalkConfigure 1 }

  eTalkNode OBJECT-TYPE
      SYNTAX  OCTET STRING (SIZE (1))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "Indicates the EtherTalk node number that the print
           server is currently using."
      ::= { eTalkConfigure 2 }

  eTalkNumPorts OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "Indicates the number of physical output ports that
           are EtherTalk compatible."
      ::= { eTalkConfigure 3 }

  eTalkPortTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF ETalkPortEntry
      ACCESS  not-accessible
      STATUS  optional
      DESCRIPTION
           "A table of EtherTalk specific port configuration
           information."
      ::= { eTalkConfigure 4 }

  eTalkPortEntry OBJECT-TYPE
      SYNTAX  ETalkPortEntry
      ACCESS  not-accessible
      STATUS  optional
      DESCRIPTION
           "An entry of EtherTalk port specific information."
      INDEX   { eTalkPortIndex }
      ::= { eTalkPortTable 1 }

  ETalkPortEntry ::=
      SEQUENCE {
          eTalkPortIndex
              INTEGER,
          eTalkPortEnable
              INTEGER,
          eTalkName
              DisplayString,
          eTalkActiveName
              DisplayString,
          eTalkType1
              DisplayString,
          eTalkType2
              DisplayString,
          eTalkZone
              DisplayString,
          eTalkActiveZone
              DisplayString
      }

  eTalkPortIndex OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "A unique value for each physical output port which is
           compatible with EtherTalk.  Its value ranges between
           1 and the value of eTalkNumPorts.  The value for each
           port must remain constant at least from one
           re-initialization of the entity's network management
           system to the next re-initialization."
      ::= { eTalkPortEntry 1 }

  eTalkPortEnable OBJECT-TYPE
      SYNTAX  INTEGER {
          no(1),
          yes(2)
      }
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Indicates whether or not the physical output port is
           enabled to print via EtherTalk and will show up in the
           Chooser."
      ::= { eTalkPortEntry 2 }

  eTalkName  OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (1..32))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "This is the EtherTalk name for the print server."
      ::= { eTalkPortEntry 3 }

  eTalkActiveName  OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (1..32))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "This is the EtherTalk name for the print server
           that is currently being used."
      ::= { eTalkPortEntry 4 }

  eTalkType1  OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (1..32))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Indicates the first EtherTalk type.  This type is
           mandatory."
      ::= { eTalkPortEntry 5 }

  eTalkType2  OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..32))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Indicates the second EtherTalk type.  This type is
           optional.  Setting this name to NULL will disable it."
      ::= { eTalkPortEntry 6 }

  eTalkZone  OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (1..32))
      ACCESS  read-write
      STATUS  optional
      DESCRIPTION
           "Indicates the EtherTalk zone.  This must be defined
           on the router."
      ::= { eTalkPortEntry 7 }

  eTalkActiveZone  OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (1..32))
      ACCESS  read-only
      STATUS  optional
      DESCRIPTION
           "Indicates the EtherTalk zone that is currently being
           used.  This must be defined on the router."
      ::= { eTalkPortEntry 8 }

  eTalkError  OBJECT-TYPE
       SYNTAX  DisplayString (SIZE (0..80))
       ACCESS  read-only
       STATUS  optional
       DESCRIPTION
            "Shows any errors for the EtherTalk protocol."
       ::= { eTalkStatus 1 }

  -- Traps

  trapPrinterOnline TRAP-TYPE
       ENTERPRISE printServers
       VARIABLES  {outputIndex}
       DESCRIPTION
            "The printer is on-line.  This trap will be sent
            out after a printer error condition has been cleared."
                        --#TYPE "Printer On-Line"
                        --#SUMMARY "Port %s is On-Line"
                        --#ARGUMENTS{0}
                        --#SEVERITY INFORMATIONAL
                        --#TIMEINDEX 2
                        --#STATE  OPERATIONAL
       ::= 1

  trapPrinterOffline TRAP-TYPE
       ENTERPRISE printServers
       VARIABLES  {outputIndex}
       DESCRIPTION
            "The printer is off-line."
                        --#TYPE "Printer Off-Line"
                        --#SUMMARY "Port %s is Off-Line"
                        --#ARGUMENTS {0}
                        --#SEVERITY INFORMATIONAL
                        --#TIMEINDEX 2
                        --#STATE  NONOPERATIONAL
       ::= 2

  trapNoPrinterAttached TRAP-TYPE
       ENTERPRISE printServers
       VARIABLES  {outputIndex}
       DESCRIPTION
            "No printer is attached to the output port."
                        --#TYPE "No Printer Attached"
                        --#SUMMARY "Port %s - No Printer Attached"
                        --#ARGUMENTS {0}
                        --#SEVERITY INFORMATIONAL
                        --#TIMEINDEX 2
                        --#STATE  NONOPERATIONAL
       ::= 3

  trapPrinterTonerLow TRAP-TYPE
       ENTERPRISE printServers
       VARIABLES  {outputIndex}
       DESCRIPTION
            "The printer toner is low."
                        --#TYPE "Toner Low"
                        --#SUMMARY "Port %s - Toner Low"
                        --#ARGUMENTS {0}
                        --#SEVERITY MINOR
                        --#TIMEINDEX 2
                        --#STATE  DEGRADED
       ::= 4

  trapPrinterPaperOut TRAP-TYPE
       ENTERPRISE printServers
       VARIABLES  {outputIndex}
       DESCRIPTION
            "The printer is out of paper."
                        --#TYPE "Printer Out of Paper"
                        --#SUMMARY "Port %s - Out of Paper"
                        --#ARGUMENTS {0}
                        --#SEVERITY MINOR
                        --#TIMEINDEX 2
                        --#STATE  NONOPERATIONAL
       ::= 5

  trapPrinterPaperJam TRAP-TYPE
       ENTERPRISE printServers
       VARIABLES  {outputIndex}
       DESCRIPTION
            "The printer has a paper jam."
                        --#TYPE "Paper Jam"
                        --#SUMMARY "Port %s - Paper Jam"
                        --#ARGUMENTS {0}
                        --#SEVERITY MAJOR
                        --#TIMEINDEX 2
                        --#STATE  NONOPERATIONAL
       ::= 6

  trapPrinterDoorOpen TRAP-TYPE
       ENTERPRISE printServers
       VARIABLES  {outputIndex}
       DESCRIPTION
            "The printer door is open."
                        --#TYPE "Printer Door Open"
                        --#SUMMARY "Port %s - Printer Door Open"
                        --#ARGUMENTS {0}
                        --#SEVERITY INFORMATIONAL
                        --#TIMEINDEX 2
                        --#STATE  NONOPERATIONAL
       ::= 7

  trapPrinterError TRAP-TYPE
       ENTERPRISE printServers
       VARIABLES  {outputIndex}
       DESCRIPTION
            "General printer error."
                        --#TYPE "General Printer Error"
                        --#SUMMARY "Port %s - Printer Error"
                        --#ARGUMENTS {0}
                        --#SEVERITY MINOR
                        --#TIMEINDEX 2
                        --#STATE  NONOPERATIONAL
       ::= 16
END